Mahsulot afzalliklari
Nima uchun bu 241 kVt / soat quvvatga ega BESS shkafi ajralib turadi?
A darajasi LiFePO4 · 314Ah
1P240S yagona-string - parallel nomutanosiblik yoʻq. 100% zavod-ekranlangan IEC 62620 boʻyicha 3mV dan kam yoki unga teng.
Suyuqlik / havo sovutish sozlanishi
Glycol cold plates for >40 darajali muhit: ±2 daraja hujayra bir xilligi, issiq hududlarda sovutilgan havoga nisbatan 15–20% uzoqroq aylanish muddati.
Hammasi-bir{1}}bir modulli integratsiya
Batareya + PCS + BMS + EMS + STS + sovutish + bitta IP55 tashqi korpusda yong'inni o'chirish. Saytda yig'ish- nol.
5-qatlamli xavfsizlik arxitekturasi
Hujayra BMS → modul sug'urtasi → raf termal to'sig'i → shkafning yong'inga qarshi → tizimni favqulodda o'chirish. Har bir mustaqil.
DC Round -Sayohat samaradorligi 89% dan katta yoki unga teng
IGBT-based PCS. AC-AC ≥86%. Liquid-cooled maintains 1–2% higher efficiency in >40 darajali muhit.
Bulutli EMS + Masofaviy O&M
Haqiqiy{0}}vaqtdagi SOC/SOH/power/temperature asboblar paneli. Anomaliyalar haqida ogohlantirishlar. OTA proshivka yangilanishlari. SCADA integratsiyasi uchun API.
Tizim arxitekturasi
Integratsiyalashgan kabinet BESS ichida
Oltita quyi tizim, bitta muhofaza. Hech qanday tashqi moslashuv talab qilinmaydi.
125KVt quvvatga ega ikki yoʻnalishli shaxsiy kompyuterlar-
Grid-bog'langan + o'chirilgan-tarmoq rejimlari. STS 20ms dan kam yoki unga teng uzatish. 380V/400V/415V 3 fazali, 50/60Hz.
Energiya boshqaruv tizimi (EMS)
Soqol olishning eng yuqori darajasi, TOU arbitraji, quyoshdan foydalanish-, talabga javob. SCADA API.
Batareya boshqaruv tizimi (BMS)
Hujayra-darajali V/I/T monitoringi. 240S string bo'ylab faol balanslash. SOC/SOH ±2% aniqlik.
Statik uzatish kaliti (STS)
Sub{1}}20ms grid↔off-to‘r. UPS-kritik yuk uzluksizligi darajasi.
Issiqlik boshqaruvi va sovutish
Havo: IP55 majburiy shamollatish. Suyuqlik: glikolli sovuq plitalar, ± 2 daraja bir xillik.
Yong'inni o'chirish tizimi
Tutun/gazni aniqlash → aerozol tezkor → perfluorogeksanon suv bosishi. Nol qoldiq.
241 kVt soat Kabinet BESS spetsifikatsiyasi
Batareya parametri
| Model | CBS240 | |
| Nominal kuchlanish | 768V | |
| Nominal quvvat | 314Ah | |
| Energiya | 241 kVt/soat | |
| Ishlash kuchlanish diapazoni | 624-864V | |
| Seriya va parallel ulanish | 1P240S | |
Tizim parametri
| Standart tarmoq | 3L+N+PE |
| Nominal quvvat | 125 kVt |
| Tarmoq kuchlanish diapazoni | 380V (-15% dan +10%) |
| Nominal oqim | 190A |
| Maksimal konvertatsiya samaradorligi | 97% |
| Ortiqcha-yuklash qobiliyati | 110% 1 min |
| Nominal chastota | 50Hz |
| Tarmoq chastota diapazoni | 50Hz±2,5Hz |
| Gridning umumiy buzilish darajasi (THDi) | To'liq yukda 3% dan kam yoki teng |
| Uch fazali -balanssizlik darajasi | 100% |
| Quvvat omili | -1~+1 sozlanishi |
Umumiy parametr
| Sovutish tizimi | Suyuq sovutish (havo sovutish ixtiyoriy) |
| Yong'in o'chirish tizimi | Perflorogeksanon + aerozol ikki bosqichli- |
| Ishlash harorati | -20 ~ 50 daraja |
| Shovqin | 60dB dan kam yoki unga teng |
| IP darajasi | IP54 |
| Hajmi (W×D×H) | 1195×1400×2140mm (47,1×55,1×84,3 dyuym) |
| Og'irligi | 2,8 tonnadan kam yoki unga teng |
Eslatma:Standart shartlar. Sovutish, invertor, loyiha uchun sozlanishi sertifikatlar.To'liq ma'lumotlar jadvalini yuklab oling (PDF)
Kabinet BESS bir nechta jahon miqyosida tan olingan inverter ishlab chiqaruvchilari tomonidan rasman mos keladigan ro'yxatga kiritilgan. Har bir mahsulot uzluksiz aloqa, ishonchli ishlash va turli xil inverter platformalarida to'liq muvofiqlikni ta'minlash uchun qattiq sinov va tekshirishdan o'tgan.












Sertifikatlar

241kWh Kabinet BESS - Texnik savollar
Savol: Nima uchun 241 kVt/soat parallel simlar o‘rniga 1P240S dan foydalanadi va buning haqiqiy-dunyoga ta'siri qanday?
Javob: 1P240S 240 ta katakchani nol parallel satrlar bilan ketma-ket qo'yadi. Bu koʻp parallel konstruksiyalarda sigʻimning muddatidan oldin susayishining asosiy sababi boʻlgan -torlararo oqim nomutanosibligini - yoʻq qiladi. Faqat bitta qator bilan BMS oddiyroq, bashorat qilinadigan zaryad/zaryad rejimini boshqaradi. Imtiyozli-har bir 314Ah quvvatli hujayra havolaning zaif buzilishiga yo'l qo'ymaslik uchun qattiqroq kirish tekshiruvidan o'tishi kerak (3mV dan kam yoki unga teng, 5mŌ dan kam yoki unga teng). Amalda, bu 241,15 kVt/soat - bo‘ylab foydalanuvchilar o‘xshash umumiy quvvatga ega 2P yoki 4P arxitekturalariga nisbatan 3 va 10 yillar oralig‘ida kamroq SOH farqini ko‘rishadi.
Savol: Agar hujayra bu kabinet ichida termal qochib ketsa, uning qo'shni modullarga etib borishiga nima to'sqinlik qiladi?
Javob: Besh qatlam ketma-ket yonadi: hujayra BMS anomaliyani belgilaydi<500ms and isolates it; module fuses cut fault current before propagation; rack-level ceramic barriers block heat transfer physically; if temperature or gas levels still rise, the cabinet's perfluorohexanone + aerosol system floods the compartment automatically (no residue, no electronic damage); and finally the STS disconnects the entire cabinet from the grid in ≤20ms. Because this is LiFePO4 - not NCM or NCA - the failing cell does not release oxygen, which is the main propagation driver in ternary chemistries. No layer depends on another to function. For a deeper look at how UL testing validates these safety layers, see our guide on BESS UL sertifikati.
Savol: 241 kVt / soat nominal, lekin to'liq tsiklda qancha AC energiyasi chiqadi?
A: At default EMS settings (5% bottom SOC reserve, 2% top), usable DC capacity is ~224 kWh per cycle. Multiply by ≥86% AC-AC round-trip efficiency (at 25°C, 0.5C) and you get roughly 193–207 kWh AC delivered to load - the range depends on ambient temperature and C-rate. In hot climates (>40 daraja), suyuqlik{1}}sovutilgan variant havo sovutilganga qaraganda 1–2% yuqori samaradorlik beradi-, chunki qattiqroq issiqlik nazorati ichki qarshilikni pasaytiradi. Agar loyihangiz maksimal ishlab chiqarishni talab qilsa, EMS SOC zahiralari sozlanishi -, ammo torroq zaxiralar qisqa muddatli quvvat uchun uzoq umr ko'radi.
Savol: Bu shkafning og‘irligi 2,8 tonnadan kam yoki unga teng - uni qo‘llab-quvvatlash uchun sayt nimaga muhtoj?
Javob: Poydevor: tekis beton yostiq yoki po'latdan yasalgan ramka 4000 kg dan katta yoki unga teng. Jihoz (1400 × 1300 × 2387 mm) xizmat ko'rsatish uchun old tomondan 800 mm, shamollatish uchun boshqa tomondan 300 mm bo'sh joy kerak. Standart 3,5 t dan katta yoki unga teng bo'lgan forklift uni kransiz - joylashtira oladi. Elektr: 3{16}}fazali 380/400/415V AC ulanishi, mahalliy kodli topraklama, Ethernet yoki EMS uchun RS485 kabeli. Polinovel har bir buyurtma bilan o'lchamli poydevor chizmalarini va kabel yo'riqnomalarini jo'natadi va video qo'ng'iroq orqali bepul masofadan ishga tushirishni taklif qiladi.
Savol: Men 241 kVt quvvatga ega ushbu shkaflarning 4–8 tasini parallel qilganimda, EMS notekis qarishni qanday oldini oladi?
A: The centralized EMS runs a weighted SOC balancing algorithm each control cycle (~100ms): cabinets with higher SOC discharge proportionally more, lower-SOC units receive more charge current. This keeps all cabinets within a tight SOC band and prevents any single unit from cycling disproportionately - which is the main cause of uneven aging in parallel BESS systems. Each cabinet retains independent BMS and PCS, so if one trips on a fault, the others absorb its load seamlessly. Communication: Modbus-TCP over Ethernet, 1-second polling. For systems >2 MVt soat, Polinovel tavsiya qiladikonteynerlangan BESSmiqyosda yaxshiroq $/kVt/soat uchun.
Savol: 125 KVt quvvatga ega shaxsiy kompyuterlar bir xil o‘rnatishda kunduzi{1}}bog‘langan eng yuqori soqol olish va kechasi-tormozdan tashqari zaxira nusxasini olishi mumkinmi?
Javob: Ha - EMS vaqtni-rejalashtirilgan rejimga almashtirishni qo‘llab-quvvatlaydi. Misol: tarmoq-bog'langan TOU arbitraji soat 6:00–22:00, avtomatik o'chirilgan-tarmoq zahiralari 22:00–6:00. STS har bir o'tishni 20 ms dan kamroq yoki unga teng tezlikda bajaradi. Ayrim yuklarni tarmoq-bog‘lash, boshqalari esa bir vaqtning o‘zida-tormozdan uzilishi (ajratilgan-avtobus) uchun standart konfiguratsiyadan tashqari qo‘shimcha o‘tkazgich moslamalari talab qilinadi.Polinovel muhandislik bilan bog'laningajratilgan{0}}avtobus loyihasi koʻlami va narxlari uchun.
C&I energiya saqlash uchun texnik tushunchalar

2025 yilda BESS aslida qancha turadi?
Kabinet va konteyner loyihalari uchun kalit taslim narxlar, yashirin xarajatlar va ROI metodologiyasi.

Katta oʻlchamli energiya saqlash - Nima oʻzgardi?
Davomiylik almashinuvi-, ishlab chiqarish cheklovlari va nima uchun EMS dasturiy ta'minoti odamlar o'ylagandan ham muhimroq.

Kabinetdan BESS konteyneriga qachon o'lchash kerak
Imkoniyatlar chegaralari, xarajatlarning to'xtash nuqtalari va shakl omillari bo'yicha qarorlar tizimi.
Issiq teglar: 125kw 241kwh tashqi shkafi energiya saqlash tizimi, Xitoy 125kw 241kwh tashqi shkafi energiya saqlash tizimi ishlab chiqaruvchilar, etkazib beruvchilar, zavod